Every battery needs care! It is a myth that a lithium battery requires no maintenance or cannot break. Every battery must be properly recharged regularly, including lead-acid batteries (AGM, Gel) and lithium batteries. To guarantee a long life cycle, a lead-acid battery should never be discharged deeper than 50%. Regularly charging properly (with the right charger) prevents loss of capacity. Voltages below 12V should be avoided. If the lights in your vehicle or vessel are dim, or the heater won’t start, then the battery is truly empty. This causes irreversible damage to traditional lead-acid batteries.
A lithium battery can be your loyal partner for 15 to 20 years, provided you treat it well: A lithium battery must always be protected by a BMS (Battery Management System). Deep discharging the batteries is permitted, as a good BMS will intervene in time, but… There is one condition: after a deep discharge, the battery must be recharged immediately. In a healthy, high-quality lithium battery, the electronics ensure your safety. The components have a continuous minimal power consumption, even if your battery has been preventively shut down by the BMS due to deep discharge. If you leave the battery completely discharged, the minimal self-consumption can cause irreparable damage to the battery after a few weeks!
This is the fate of some batteries left behind in winter storage. A 12V lithium battery that drops below 8 Volts is irrevocably defective. Unfortunately, such batteries are not eligible for warranty.
Every lithium battery sold by VENSTAR is a SAFE BATTERY. In addition to the MANDATORY CE CERTIFICATION, most also have an E-MARK certification. The E-mark, also known as the “automotive certification,” is mandatory for batteries installed in vehicles. This certification is a form of (mechanical) test certificate. The tests are based on factors such as vibrations and other properties that are important for use in vehicles.
Proper battery management is essential for the long life of your lead-acid or lithium battery. With a lead-acid battery, the voltage is more or less related to the percentage: take a healthy battery where you read 12V. You can then assume that it is approximately 50% discharged.
Nowadays, we want to know more accurately how the energy management is performing: this can be done with a battery monitor or potentially via an app (built into the lithium battery). Every accurate measurement is performed via a so-called “shunt.”
The shunt registers the incoming and outgoing current and calculates this against the battery capacity to arrive at a percentage. There will always be a small deviation: a difference will arise every time there is partial charging or discharging. Over time, these differences accumulate. The discrepancy increases! The percentage, also known as SOC (state of charge), then no longer corresponds to reality.
Solution: by fully charging the battery, the battery monitor will reset itself and provide a correct reading again. If, for example, charging is only done via solar panels and the batteries never reach a 100% charge range (winter), a large margin of error can occur in the SOC reading on the battery monitor.
A booster is essentially a battery charger that operates on 12 (or 24) volts: the input voltage may fluctuate, but the output charging voltage will always be correct for charging a second set of batteries. The variable and often insufficient voltages in Euro6 vehicles make it impossible to properly charge a second set of batteries. A booster ensures you receive the correct voltage to charge the batteries properly and efficiently.
When charging lithium batteries from a starter battery, a booster must always be installed. In this case, in addition to providing the correct voltage, the booster also prevents the lithium battery from being overcharged. It provides extra safety.
When connecting an inverter, MultiPlus, or Quattro, the capacitors inside the device can generate a significant spark. This spark is visible when making the final connection. If you use a main switch as the final connection, the spark will jump internally within the switch. Due to this momentary high current, the switch contacts can burn out (become defective) or the battery poles and connection terminals on the device can be damaged. It is better to give a quick “tap” with the cable on a surface where damage remains very limited (for example, a busbar or fuse).
The truly correct solution is to use a “pre-charge resistor.” This resistor is used to establish a connection first before closing the main switch. Bridging for a few seconds via a pushbutton with a resistor of, for example, 50 watts-25 ohms can entirely prevent both sparks and damage! When you buy from Venstar, we naturally provide all the tips you need for a safe installation!
A Victron MultiPlus is a combined battery charger and inverter: when the system is connected to the grid, it will automatically charge the batteries and provide mains power to all outlets. If the plug is removed from the external grid, the MultiPlus automatically switches to inverter mode: the outlets are powered via the battery and the inverter. The MultiPlus therefore always guarantees 230 Volts!
When power is limited to, for example, 6 Amps at a campsite or marina, this limit can be configured. The MultiPlus or Quattro can provide their inverter capacity in parallel with the grid. This allows you to turn 6A into 16A, for example, so you aren’t affected by the limited current (or blown fuses at the campsite!).